<LOGO>
FM Transmitter Measurement Report
Created: 2025-09-29 23-23-15
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.10 MHz 4/5, 61 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz 3.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
4 kHz 75 kHz 5218 10,5788
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,7 dBr 8,08 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 1 23:23, 29.09.2025
RT
-
AF EON
87.6, 87.7, 90.2, 90.4, 90.6, 92.3, 95.3, 96.4, 97.3, 99.1, 100.7, 101.2, 101.6, 102.6, 103.1, 103.2, 103.3, 103.6, 104.1, 104.8, 106.7, 107.2, 107.3, 107.5, 107.9 MHz -
FM Scope Station: 103.10 MHz, signal: 4/5 (61 dBuV) Max at: 75 kHz MIN: 4 kHz % above 75 kHz: 10,5788 Acquired: 2025/09/29 23:22:11 Total samples: 5218 Equivalent time: 0:04:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500
FM Scope MAX: 8,3 dBr MIN: 7,7 dBr AVE: 8,08 dBr % above 10,2 dBr: 0,0 Last value: 8,0 dBr (2025/09/29 23:22:11) Station: 103.10 MHz, signal: 4/5 (61 dBuV) 23:15 23:16 23:17 23:18 23:19 23:20 23:21 23:22 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality